CL10H Skin Cooler – Laser Treatment Pain Relief
Overview
The CL10H Cold Air Skin Cooling System is a high-performance medical-grade cooling device designed to significantly enhance patient comfort and treatment safety during a wide range of dermatological and aesthetic procedures. By delivering a continuous stream of chilled air as low as -20°C, it effectively minimizes pain, reduces the risk of thermal injury, and allows practitioners to use higher energy settings for improved treatment outcomes. Ideal for use with laser, IPL, and injection-based therapies, the CL10H is an essential tool for modern clinics aiming to offer pain-free and efficient services.
How It Works
The CL10H employs an advanced frequency conversion air compressor to compress ambient air, which is then cooled through a dedicated refrigeration system. This process generates a consistent flow of cold air that is directed onto the treatment area, providing immediate and controlled cooling before, during, and after procedures. This mechanism not soothes the skin and reduces discomfort but also protects the epidermis, enabling safer delivery of high-energy treatments.
Key Features & Benefits
1. Superior Cooling Performance
Delivers a continuous stream of cold air reaching temperatures as low as -20°C.
Effectively numbs the skin, reducing pain and patient anxiety during procedures.
Minimizes the risk of burns, swelling, and post-treatment redness.
2. Fully Adjustable Settings
9-level wind speed control (0–0.5 m³/min) for customized patient comfort.
Programmable treatment timer from 1 to 60 minutes.
Large 7-inch touch screen for intuitive operation and real-time monitoring of all parameters.
3. Broad Device Compatibility
Works seamlessly with:
808nm diode laser systems
CO₂ fractional lasers
SHR (Super Hair Removal) devices
IPL (Intense Pulsed Light) machines
Nd:YAG lasers
And other energy-based aesthetic equipment
4. User-Friendly Design
No consumables or recurring costs—economical and low-maintenance.
Built-in auto-defrost function ensures consistent performance during extended use.
Water drainage alarm alerts users when maintenance is required.
Mobile and compact design (320×450×350 mm) with durable construction.
5. Enhanced Safety Protocols
Automatic defrost cycle activates when needed to maintain efficiency.
Safe operation ensured with adjustable distance recommendations (nozzle at least 8 cm from skin).
Includes safety alerts for water drainage and system errors.
Technical Specifications
| Parameter | Specification |
|---|---|
| Power Supply | 220V / 110V |
| Power Consumption | 500W |
| noise Level | <60 dB |
| Air Flow Rate | 0–0.5 m³/min (9 adjustable levels) |
| Minimum Temperature | -20°C (at 25°C ambient, 30% humidity) |
| Treatment Timer | 1–60 minutes (programmable) |
| Net Weight | 26 kg |
| Unit Dimensions (LxWxH) | 320 × 450 × 350 mm |
| Package Dimensions | 560 × 430 × 500 mm |
Applications
The CL10H is widely used in conjunction with:
Laser hair removal
Fractional laser skin resurfacing
IPL photorejuvenation and vascular treatments
Tattoo removal
Cosmetic injectables (e.g., numbing before filler injections)
Post-treatment cooling to reduce swelling and soothe skin
Operating Guidelines
Initial Setup
Upon receipt, allow the unit to stand upright for at least 3 hours before first use.
Ensure the unit is placed on a flat, stable surface to minimize vibration.
Avoid tilting the device beyond 30° during transport or operation.
Usage Instructions
Press the power button to initiate the cooling system.
Select desired wind speed (1–9) and treatment time via the touch screen.
Direct the airflow nozzle 8–10 cm above the skin surface.
Monitor patient comfort and adjust settings as needed.
Maintenance & Safety
Defrosting: The system includes an automatic defrost function. Manual defrost can also be initiated via the control panel when necessary.
Water Drainage: If the water tank alarm activates, power off the unit, drain water via the rear outlet, and securely retighten to prevent air leakage.
Cleaning: Use a soft, dry cloth. Do not use alcohol or abrasive cleaners on the touch panel.
Transport: Always drain water before moving the unit. Do not invert or exceed 30° tilt.
Warranty & Service
12-month warranty provided for manufacturing defects (mainland China).
Coverage includes free repair or part replacement under warranty terms.
Damage resulting from misuse, unauthorized modification, natural disasters, or improper maintenance is not covered.
Why Choose the CL10H?
Clinical Efficiency: Enables higher laser fluences and faster treatment times.
Patient Comfort: Significantly reduces pain and improves overall experience.
Versatility: Compatible with all major laser and light-based platforms.
Cost-Effective: No ongoing expenses for consumables or accessories.
Shipping & Delivery
Experience reliable and efficient shipping and delivery services tailored to meet your needs. Our international shipping service ensures seamless delivery to destinations around the world. We offer:
- Reliable and Secure Delivery: Swift handling and secure packaging to safeguard your items during transit. We offer packaging options including wooden cases, cartons, aluminum cases, and standard export packing depending on the product.
- Tracking and Updates: Stay informed with real-time tracking and regular updates on your shipment's progress.
- Flexible Options: Enjoy flexible options with our logistics services. Choose from a range of delivery speeds and service levels to suit your timeline and budget. Our free logistics service includes rail and sea shipping, typically taking 22-45 working days. Additionally, you can opt for express delivery, which arrives within 7-15 days for an added cost. With express delivery, you'll manage customs fees and clearance independently, while we provide necessary customs clearance documents upon request.